The risk of fire occurring in building compartment – what are the consequences if it is assumed to be time-independent
cytuj
pobierz pliki
RIS BIB ENDNOTEWybierz format
RIS BIB ENDNOTEThe risk of fire occurring in building compartment – what are the consequences if it is assumed to be time-independent
Data publikacji: 26.09.2014
Czasopismo Techniczne, 2013, Budownictwo Zeszyt 3-B (9) 2013, s. 43 - 51
https://doi.org/10.4467/2353737XCT.14.063.3971Autorzy
The risk of fire occurring in building compartment – what are the consequences if it is assumed to be time-independent
The acceptance in advanced fire safety analysis of the formal model according to which the probability of fire occurrence is assumed as time-independent leads to the conclusion that random fire episodes in considered building compartment can be described by the formalism of a Poisson process. In the presented paper some consequences of such adoption are presented and widely discussed as well as the foundations are determined of the equivalence between this probability and a conditional failure rate, which is interpreted as a process intensity parameter.
PN -EN 1990 Eurocode – Basis of Structural Design.
Maślak M., Prawdopodobieństwo katastrofy ustroju nośnego budowli w warunkach pożaru, Czasopismo Techniczne, 12-B/2005, 67–80.
Maślak M., Selected aspects of failure probability assessment for fire situation, Archives of Civil Engineering, LVII , 3, 2011, 297–311.
Lie T.T., Optimum Fire Resistance of Structures, Journal of the Structural Division, 98, ST 1, 1972, 215-232.
Maślak M., Measures of the risk of fire occurrence – interpretation and quantification, Proceedings of IABSE Conference “Global Thinking in Structural Engineering: Recent Achievements”, Sharm El Sheikh, Egypt, May 7-9, 2012, IABSE Report, vol. 98, 174-175 (abstract) + CD (6 pages).
Kersken-Bradley M., Basic Notes on Structural Fire Protection, Proceedings of XI JCSS Meeting, Lisbon, Portugal, April 21-22, 1980.
BSI DD240, Fire Safety Engineering in Building, Part 1: Guide to the Application of Fire Safety Engineering Principles, British Standard Institution, 1997.
DIN 18230, Baulicher Brandschutz im Industrienbau, Teil 1: Rechnerisch Erforderliche Feuerwiderstandsdauer, Beuth Verlag Gmbh, Berlin, Germany, 1995.
JCSS , Probabilistic Model Code, Part 2: Load Models, 2.20 Fire, Joint Committee on Structural Safety, Zurich, Switzerland, 2001.
Schleich J.-B, Cajot L.B., et al., Competitive Steel Buildings through Natural Fire Safety Concept, ECSC Research 1210-SA /125, 126, 213, 214, 323, 423, 522, 623, 839, 937, 194-98, Final Report EUR 20360EN , European Coal and Steel Community, Esch/ Alzette, Luxembourg 2002.
Burros R.H., Probability of Failure of Building from Fire, Journal of the Structural Division, ST 9, September 1975, 1947-1960.
Benjamin J.R., Cornell C.A., Rachunek prawdopodobieństwa, statystyka matematyczna i teoria decyzji dla inżynierów, Wydawnictwa Naukowo-Techniczne, Warszawa 1977.
Informacje: Czasopismo Techniczne, 2013, Budownictwo Zeszyt 3-B (9) 2013, s. 43 - 51
Typ artykułu: Oryginalny artykuł naukowy
Tytuły:
The risk of fire occurring in building compartment – what are the consequences if it is assumed to be time-independent
The risk of fire occurring in building compartment – what are the consequences if it is assumed to be time-independent
Cracow University of Technology
Publikacja: 26.09.2014
Status artykułu: Otwarte
Licencja: Żadna
Udział procentowy autorów:
Korekty artykułu:
-Języki publikacji:
AngielskiLiczba wyświetleń: 1827
Liczba pobrań: 1149