Permanent magnet synchronous motors are often used in hybrid electric vehicles due to the high power density. Overheating in a PMSM motor can cause negative effects on the work of permanent magnets and a significant shortening of the life of the machine due to the phenomenon of the thermal ageing of insulation. Therefore, it is extremely important to know the exact temperature distribution in different parts of the electrical machine under various operating conditions. This paper presents a lumped parameter thermal model and FE model of a permanent magnet synchronous motor. A method for the homogenization of a stator winding is also described. In order to validate the accuracy of the calculation results, measurements on the physical model of the machine were carried out.
Idoughi L., Mininger X., Bouillault F., Bernard L., Hoang E., Thermal Model with Winding Homogenization and FIT Discretization for Stator Slot, IEEE Transactions on Magnetics, December 2011, Vol. 47, No. 12, pp. 4822–4826.
Kowol M., Mynarek P., Kołodziej J., Application of LabVIEW environment for permanent magnet synchronous motor testing, Poznan University of Technology, Academic Journals, Electrical Enginnering, Computer Applications in Electrical Enginnering, Issue 75, Poznań 2013, pp. 49– 56.
Lee B., Kim K., Jung J., Hong J., Kim Y., Temperature Estimation of IPMSM Using Thermal Equivalent Circuit, IEEE Transactions on Magnetics, November 2012, Vol. 48, No. 11, pp. 2949–2952.
Nategh S., Wallmark, O., Leksell M., Zhao S., Thermal Analysis of a PMaSRM Using Partial FEA and Lumped Parameter Modeling, IEEE Transactions on Energy Conversion, June 2012, Vol. 27, No. 2, pp. 477–488.
Simpson N., Wrobel R., Mellor P.H., Estimation of Equivalent Thermal Parameters of Impregnated Electrical Windings, IEEE Transactions on Industry Applications, Nov.–Dec. 2013, Vol. 49, No. 6, pp. 2505–2515.
Wrobel R., Mellor P.H., McNeill N., Staton D.A., Thermal Performance of an Open-Slot Modular-Wound Machine with External Rotor, IEEE Transactions on Energy Conversion, 2010, Vol. 25, No. 2, pp. 403–411.
Wrobel R., Mellor P.H., Thermal Design of High-Energy-Density Wound Components, IEEE Transactions on Industrial Electronics, September 2011, Vol. 58, No. 9, pp. 4096–4104.
Informacje: Czasopismo Techniczne, 2015, Elektrotechnika Zeszyt 1-E (8) 2015, s. 97-107
Typ artykułu: Oryginalny artykuł naukowy
Tytuły:
Thermal analysis of a pm sm using fea and lumped parameter modeling
Thermal analysis of a pm sm using fea and lumped parameter modeling
Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Science and Technology
Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Science and Technology
Publikacja: 16.12.2015
Status artykułu: Otwarte
Licencja: Żadna
Udział procentowy autorów:
Korekty artykułu:
-Języki publikacji:
AngielskiLiczba wyświetleń: 1908
Liczba pobrań: 1947