FAQ

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Data publikacji: 28.03.2014

Czasopismo Techniczne, 2013, Mechanika Zeszyt 1-M (5) 2013 , s. 365 - 372

https://doi.org/10.4467/2353737XCT.14.046.1972

Autorzy

Jolanta Stacharska-Targosz
Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology
Wszystkie publikacje autora →

Tytuły

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Abstrakt

In this paper the problem of volumetric flow rate regulation is considered. The change of angular position of an element mounted axially inside of the cross flow fan impeller creates different aerodynamic performances: yt = f (j), ys = f (j) at the same rotational speed and in consequence the qualitative diversification of fan operation is obtained. It gives possibility to use a cross flow fan for several applications depending on an actual requirement respecting to volumetric flow rate or pressure coefficient. The shape of inner element as well as its angular position have an important influence on the flow structures so a method of volumetric flow rate control without necessity of rotational speed change is proposed. This way of cross flow fan flow rate control, commonly made with use of frequency converter, seems to be more effective for reduction of an energy consumption and gives an evidenteconomic advantage.

Bibliografia

Stacharska-Targosz J., Chmielowiec M., The influence of internal vane on uniform velocity distribution in the cross-flow fan, The Archive of Mechanical Engineering, Vol. LVI, No. 1, 2009, 61-72.

Korowkin A.G., Isslledowanije regulacjonnych elementow diametralnych wentilatorow, Promyszlennaja Aerodynamika, Wyp. 33, 1986.

Gołogorski J., Stacharska-Targosz J., Wentylatory poprzeczne o sterowalnej charakterystyce – metoda oceny działania, Chłodnictwo, t. XXVI, Nr 11 ,10-13.

Stacharska-Targosz J., Wentylatory poprzeczne, Politechnika Krakowska, Kraków 2006.

Sowa A., Flow simulation in cross flow fans using finite element and finite volume methods, TASK Quarterly, 1/2004.

Stacharska-Targosz J., Chmielowiec M., Application of finite volume method for numerical calculations of cross flow fan performance curves, Archive of Thermodynamics, Vol. 29, No. 2, 2008, 3-20.

Informacje

Informacje: Czasopismo Techniczne, 2013, Mechanika Zeszyt 1-M (5) 2013 , s. 365 - 372

Typ artykułu: Oryginalny artykuł naukowy

Tytuły:

Polski:

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Angielski:

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Autorzy

Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology

Publikacja: 28.03.2014

Status artykułu: Otwarte __T_UNLOCK

Licencja: Żadna

Udział procentowy autorów:

Jolanta Stacharska-Targosz (Autor) - 100%

Korekty artykułu:

-

Języki publikacji:

Angielski