FAQ

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Publication date: 28.03.2014

Technical Transactions, 2013, Mechanics Issue 1-M (5) 2013 , pp. 365-372

https://doi.org/10.4467/2353737XCT.14.046.1972

Authors

Jolanta Stacharska-Targosz
Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology
All publications →

Download full text

Titles

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Abstract

In this paper the problem of volumetric flow rate regulation is considered. The change of angular position of an element mounted axially inside of the cross flow fan impeller creates different aerodynamic performances: yt = f (j), ys = f (j) at the same rotational speed and in consequence the qualitative diversification of fan operation is obtained. It gives possibility to use a cross flow fan for several applications depending on an actual requirement respecting to volumetric flow rate or pressure coefficient. The shape of inner element as well as its angular position have an important influence on the flow structures so a method of volumetric flow rate control without necessity of rotational speed change is proposed. This way of cross flow fan flow rate control, commonly made with use of frequency converter, seems to be more effective for reduction of an energy consumption and gives an evidenteconomic advantage.

References

Stacharska-Targosz J., Chmielowiec M., The influence of internal vane on uniform velocity distribution in the cross-flow fan, The Archive of Mechanical Engineering, Vol. LVI, No. 1, 2009, 61-72.

Korowkin A.G., Isslledowanije regulacjonnych elementow diametralnych wentilatorow, Promyszlennaja Aerodynamika, Wyp. 33, 1986.

Gołogorski J., Stacharska-Targosz J., Wentylatory poprzeczne o sterowalnej charakterystyce – metoda oceny działania, Chłodnictwo, t. XXVI, Nr 11 ,10-13.

Stacharska-Targosz J., Wentylatory poprzeczne, Politechnika Krakowska, Kraków 2006.

Sowa A., Flow simulation in cross flow fans using finite element and finite volume methods, TASK Quarterly, 1/2004.

Stacharska-Targosz J., Chmielowiec M., Application of finite volume method for numerical calculations of cross flow fan performance curves, Archive of Thermodynamics, Vol. 29, No. 2, 2008, 3-20.

Information

Information: Technical Transactions, 2013, Mechanics Issue 1-M (5) 2013 , pp. 365-372

Article type: Original article

Titles:

Polish:

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

English:

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

Authors

Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology

Published at: 28.03.2014

Article status: Open

Licence: None

Percentage share of authors:

Jolanta Stacharska-Targosz (Author) - 100%

Article corrections:

-

Publication languages:

English

Regulation of flow rate generated by cross flow fan with use of internal vane. Experimental and numerical results

cytuj

pobierz pliki

RIS BIB ENDNOTE