Abstract

The airtightness measurements of the system buildings are very important. They allow, together with the infrared tests, to verify all undesirable system joint leaks, which significantly increase the heating energy needs. In the article the results of airtightness measurements of two flats, built in system W-70, were presented. One of the buildings is after thermal modernization. During the leakage tests the system joints were monitored with the infrared camera. Thermograms, presented in the paper, confirmed the assumption about the negative influence of joints on the total building airtightness. Described tests are a pilot studies of the problem and provide the starting point to the further measurements on the statistical level.

References

Rozporządzenie Ministra Infrastruktury w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie z dnia 12 kwietnia 2002.

PN-EN 13829 Właściwości cieplne budynków. Określenie przepuszczalności powietrznej budynków. Metoda pomiaru ciśnieniowego z użyciem wentylatora.

PN-EN 15242 Wentylacja budynków − Metody obliczeniowe do określania strumieni objętości powietrza z uwzględnieniem infiltracji.

Kim A.K., Shaw C.Y., Seasonal Variation in Airtightness of Two Detached Houses, American Society for Testing and Materials, Philadelphia 1986, 17-32.

Shaw C.Y., Jones L., Air tightness and air infiltration of school buildings, ASHRAE Transactions VOL. 85, part 1, 1979, 85-95.

Nowak K., Nowak-Dzieszko K., Badania szczelności budynków metodą ciśnieniową, Czasopismo Techniczne, 2-B/2012, 305-313.

Ligęza W., Dębowski J., A method of non-destructive evaluation of construction defects in precast concrete panel housing, 5th International Conference, Concrete and Concrete Structures, 15–16 October 2009, Žilina, Slovakia.

Dębowski J., Cała prawda o budynkach wielkopłytowych, Przegląd budowlany, 9/2012.

Dębowski J., Typowe uszkodzenia w budynkach wielkopłytowych, Przegląd budowlany, 10/2012.

Information

Information: Technical Transactions, 2014, Architecture Issue 8 A (15) 2014, pp. 129 - 136

Article type: Original article

Titles:

Polish:

Airtightness of the large panel
buildings before and after thermal modernization

English:

Airtightness of the large panel
buildings before and after thermal modernization

Authors

Institute of Building Materials and Structures, Faculty of Civil Engineering, Cracow University of Technology

Institute of Building Materials and Structures, Faculty of Civil Engineering, Cracow University of Technology

Institute of Building Materials and Structures, Faculty of Civil Engineering, Cracow University of Technology

Published at: 17.11.2014

Article status: Open

Licence: CC BY  licence icon

Percentage share of authors:

Jacek Dębowski (Author) - 33%
Katarzyna Nowak (Author) - 33%
Katarzyna Nowak-Dzieszko (Author) - 34%

Article corrections:

-

Publication languages:

English