The sustainable construction industry vs. the final phase life cycle assessments of the internal layer of industrial chimneys
The properties of ceramic construction materials used in industrial facilities are constantly changing during the second Life Cycle Assessment (LCA) phase which relates to the accumulation of harmful substances. These materials are scrapped during subsequent maintenance, upgrade or demolition of the facility and their harmful properties may impact entire ecosystems. This means that the final phase of the LCA in such facilities involves waste products that are difficult to reuse or neutralise due to the polluting effect of the harmful substances they contain. This problem with the final phase of an LCA is highlighted by the example of an industrial chimney in Poland with a height of 160 m. During modernisation, after 30 years of service, the chimney was updated by processes that include the exchange of the thermal insulation of mineral wool and the ceramic liner (made of ordinary bricks bound with cement mortar), which were replaced with foam glass and a liner with acid-resistant bricks layed with silicate putty, respectively.
[1] Ajdukiewicz A., Beton a środowisko – zasady projektowania konstrukcji betonowych z uwagi na trwałość i wpływ na środowisko, Conference Awarie Budowlane 2011, Międzyzdroje, 2011, 23-38.
[2] Barycz S., Oruba R., Demolition of technical worn out high reinforced concrete chimneys, Inżynieria Środowiska, 9/2004, 219-220.
[3] Barycz S., Oruba R., Przykład modernizacji znacznie zużytego żelbetowego komina przemysłowego, Przegląd Budowlany, 5/2010, 55-58.
[4] Baszkiewicz J., Kamiński M., Korozja Materiałów, Warsaw University of Technology, Warszawa 2006.
[5] Czarnecki L., Laproń M., Piasecki M., Wall S., Budownictwo zrównoważone budownictwem przyszłości, Inżynieria i Budownictwo, 1/2012, 18-21.
[6] Eberle A., Barnsteine M., Demolition and Dismantling of Chimneys, CICIND Report, 24.02.2008.
[7] Fangart J., Jak zagadnienia środowiskowe zmieniają wymagania podstawowe dotyczące obiektów budowlanych? Podsumowanie, Materiały Budowlane, 10/2012, 38-39.
[8] Fiertak M., Kańka S., Methods and interpretation of material testing in power sector chimneys, Proceedings of the 5th International Conference Concrete and concrete structures, Zilina, 15‒16 October 2009, 91-98.
[9] Kańka S., Materiałowe i eksploatacyjne uwarunkowania trwałości żelbetowych kominów przemysłowych, Disertation, Cracow University of Technology, Kraków 2013.
[10] Lechman M., Diagnostics of Masonry Chimneys used as Antenna Carrier, CICIND Report, 24.02.2008.
[11] Lohr R., Solar J., Brick Liners and Chimneys … again?, CICIND Report, 24.02.2008.
[12] McCauley R.A., Corrosion of Ceramic and Composite Materials, 2nd ed, Marcel Dekker, New York 1994.
[13] Model Code 2010. International Federationfor Structural Concrete, Lausanne 2010, Vol. 1, Bulleti 55 and 56, March, April 2010.
[14] Noakowski P. et. al., Wind Farms-Environmental Issues, Design, Perspectives, CICIND Report, 25.01.2010.
[15] Oruba R., Oddziaływanie środowiska przemysłowego i eksploatacji górniczej na bezpieczeństwo żelbetowych kominów przemysłowych, Monograpf No. 211., AGH, Kraków 2010.
[16] PN-EN 15804 Sustainability of construction works - Environmental product declarations - Core rules for the product category of construction products.
[17] Rakhshan K., Friess W.A., Tajerzadeh S., Evaluating the sustainability impact of improved building insulation: A case study in the Dubai residential built environment, Building and Environment, 67/2013, 105-110.
[18] Roussat N., Méhu J., Abdelghafour M., Brula P., Leaching behaviour of hazardous demolition waste, Waste Management, 28/2008, 2032-2040.
[19] Stryszewska T., Kańka S., Osady zalegające przestrzeń pomiędzy trzonem a wykładziną źródłem zagrożenia konstrukcji żelbetowych kominów przemysłowych, Materiały Ceramiczne, 3/2013, 378-386.
[20] Stryszewska T., Mechanizm korozji cegły ceramicznej w kominach energetycznych, Ochrona przed korozją, 6/2011, 282-284.
[21] Środowisko Europy – stan i perspektywy 2010, Raport KE Zrównoważone Budownictwo w UE, 2012.
[22] The CICIND Chimney Book. CICIND, Zurich 2005.
[23] Watt D., Colston B., Investing the effects of humidity and salt crystallisation on medieval masonry, Building and Environment, 35/2000, 737-749.
Informacje: Czasopismo Techniczne, 2015, Budownictwo Zeszyt 1-B (11) 2015, s. 17 - 31
Typ artykułu: Oryginalny artykuł naukowy
Tytuły:
The sustainable construction industry vs. the final phase life cycle assessments of the internal layer of industrial chimneys
The sustainable construction industry vs. the final phase life cycle assessments of the internal layer of industrial chimneys
Institute of Building Materials and Structures, Faculty of Civil Engineering, Cracow University of Technology
Institute of Building and Materials and Structures Management, Faculty of Civil Engineering, Cracow University of Technology
Instytut Materiałów i Konstrukcji Budowlanych, Wydział Inżynierii Lądowej, Politechnika Krakowska
Publikacja: 04.12.2015
Status artykułu: Otwarte
Licencja: Żadna
Udział procentowy autorów:
Korekty artykułu:
-Języki publikacji:
AngielskiLiczba wyświetleń: 1678
Liczba pobrań: 988