FAQ

Influence of discharge resistance on internal
flow structure and performances of the cross flow fan and the unit incorporating heat
exchanger

Data publikacji: 13.01.2016

Czasopismo Techniczne, 2015, Mechanika Zeszyt 2-M (7) 2015, s. 281 - 289

Autorzy

,
Jolanta Stacharska-Targosz
Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology
Wszystkie publikacje autora →
Konrad Nering
Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology
https://orcid.org/0000-0003-4168-5707 Orcid
Wszystkie publikacje autora →

Tytuły

Influence of discharge resistance on internal
flow structure and performances of the cross flow fan and the unit incorporating heat
exchanger

Abstrakt

In this paper some selected problems dealing with an influence of different throttling conditions on the flow structure inside a cross flow fan working in a unit incorporating a heat exchanger as well as on aerodynamic performances of a cross flow fan and unit have been studied. Different experimental and numerical methods have been used to verify and confirm selected flow phenomena. The local pressure loss as an effect of a heat exchanger resistance has been estimated taking into consideration some experimental results confirmed by the Finite Volume Method computation.

Bibliografia

[1] Stacharska-Targosz J., Wentylatory poprzeczne, Politechnika Krakowska, Kraków 2006.

[2] Chmielowiec M., Wyznaczanie charakterystyk aerodynamicznych wentylatorów poprzecznych za pomocą numerycznej symulacji przepływu, Praca Doktorska, Politechnika Krakowska, Kraków 2008.

[3] Matsuki K., Shinobu Y., Takushima A., Tanaka S., Experimental study of internal flow of a room air conditioner incorporating a cross flow fan, Conference Proceeding ASHRAE 3135, 1988.

[4] Wojtuń S., Analiza pracy układu wymiennik ciepła-wentylator poprzeczny, Praca doktorska, Politechnika Krakowska, Kraków 2004.

Informacje

Informacje: Czasopismo Techniczne, 2015, Mechanika Zeszyt 2-M (7) 2015, s. 281 - 289

Typ artykułu: Oryginalny artykuł naukowy

Tytuły:

Polski:

Influence of discharge resistance on internal
flow structure and performances of the cross flow fan and the unit incorporating heat
exchanger

Angielski:

Influence of discharge resistance on internal
flow structure and performances of the cross flow fan and the unit incorporating heat
exchanger

Autorzy

Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology

https://orcid.org/0000-0003-4168-5707

Konrad Nering
Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology
https://orcid.org/0000-0003-4168-5707 Orcid
Wszystkie publikacje autora →

Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology

Publikacja: 13.01.2016

Status artykułu: Otwarte __T_UNLOCK

Licencja: Żadna

Udział procentowy autorów:

Jolanta Stacharska-Targosz (Autor) - 50%
Konrad Nering (Autor) - 50%

Korekty artykułu:

-

Języki publikacji:

Angielski

Liczba wyświetleń: 1594

Liczba pobrań: 826