Analysis of switching time for pilot operated directional control valve

Data publikacji: 28.03.2014

Czasopismo Techniczne, 2013, Mechanika Zeszyt 1-M (5) 2013 , s. 341 - 348

https://doi.org/10.4467/2353737XCT.14.043.1969

Autorzy

,
Janusz Rajda
Ponar Wadowice S.A.
Wszystkie publikacje autora →
Edward Lisowski
Institute of Applied Informatics, Faculty of Mechanical Engineering, Cracow University of Technology
Wszystkie publikacje autora →

Tytuły

Analysis of switching time for pilot operated directional control valve

Abstrakt

The paper presents an analysis of switching time for pilot operated directional control valve [1–3] in a typical hydraulic system, in which the actuator is a hydraulic cylinder. A mathematical model has been built which contains equations of motion for the valve and actuator components, the balance of fluid flow, flow through the gap, and the principle of conservation of momentum and the flow curves of pressure relief valves [6, 8]. The system of equations is solved by fourthorder Runge-Kutta method. A survey to find minimal switching time has been conducted [4]. Positive overlap value, the coefficient of its movement resistance and control pressure value have significant impact on the switching time in the tested valve.

Bibliografia

Amirante R., Moscatelli P.G., Catalano L.A., Evaluation of the flow forces on a direct (single stage) proportional by means of a computational fluid dynamic analysis, Energy Conversion and Management 48, 2007, 942-953.

Amirante R., Del Vescovo G., Lippolis A., Evaluation of the flow forces on an open centre directional control valve by means of a computational fluid dynamic analysis, Energy Conversion and Management 47, 2006, 1748-1760.

Lisowski E., Domagała M., Determination of static characteristic of direct acting relief valve, Proceedings of the 1st international conference on computational methods in fluid power technology, Melbourne 2003, 211-220.

Lisowski E., Domagała M., Optimization hydraulic components using fluid-solid interaction simulation, Proceedings of 4th FPNI-PhD Symposium, Florida-Sarassota 2006, 151-159.

Lisowski E., Filo G., Zastosowanie logiki rozmytej do sterowania proporcjonalnym zaworem przelewowym, Przegląd Mechaniczny, nr 1/2002.

Momeni H., Lisowski E., CFD analysis of pilot operated relief valve, Proceedings of 5th FP -NI-PhD Symposium, Kraków 2008, 493-500.

Stryczek S., Napędy hydrostatyczne, WNT, Warszawa 1999.

Lisowski E., Rajda J., Modelowanie CFD przepływu przez zespół zaworów, Konferencja „Napędy i sterowania hydrauliczne i pneumatyczne”, Wrocław 2012.

Renn J.C., Kao T.C., Application of CFD to design a power-saving hydraulic directional two-land-four-way-valve, Proceedings of the 1st international conference on computational methods in fluid power technology, Melbourne 2003, 26-28.

Standard ISO 4401-08-07-0-94.

Manring N.D., Modeling Spool-Valve Flow Forces, University of Missouri at Columbia, 2004, ASME International Mechanical Engineering Congress and Exposition, Anaheim, USA, 2004.

Osiecki A., Napęd i sterowanie hydrauliczne maszyn. Teoria obliczenia układu, Wydawnictwo Politechniki Gdańskiej, Gdańsk 1981.

Catalogue: Ponar Wadowice. Directional spool valve, WK 460 110, 04.2001.

Informacje

Informacje: Czasopismo Techniczne, 2013, Mechanika Zeszyt 1-M (5) 2013 , s. 341 - 348

Typ artykułu: Oryginalny artykuł naukowy

Tytuły:

Polski:

Analysis of switching time for pilot operated directional control valve

Angielski:

Analysis of switching time for pilot operated directional control valve

Autorzy

Ponar Wadowice S.A.

Institute of Applied Informatics, Faculty of Mechanical Engineering, Cracow University of Technology

Publikacja: 28.03.2014

Status artykułu: Otwarte __T_UNLOCK

Licencja: Żadna

Udział procentowy autorów:

Janusz Rajda (Autor) - 50%
Edward Lisowski (Autor) - 50%

Korekty artykułu:

-

Języki publikacji:

Angielski