Sebastian Pater
Czasopismo Techniczne, Mechanika Zeszyt 1-M (1) 2016, 2016, s. 171 - 182
https://doi.org/10.4467/2353737XCT.16.017.4981This paper presents hybrid heating and cooling system with four heating devices, three of which are producing heat from renewable energy sources. The systems operate in real conditions in residential and commercial building near Cracow. Geothermal heat pumps have an additional working mode that can be used for passive cooling during summertime for the cooling of building interiors. Results from several years of installation operation with a particular emphasis upon performance, the consumption of electricity, and the amount of heating and cooling production achieved by the individual devices have been presented.
Sebastian Pater
Czasopismo Techniczne, Volume 5 Year 2017 (114), 2017, s. 185 - 194
https://doi.org/10.4467/2353737XCT.17.080.6437W artykule przedstawiono kilka sposobów obliczania teoretycznych i rzeczywistych wartości współczynników wydajności parowych sprężarkowych pompy ciepła w krótkim i długim okresie. Różnice w obliczeniach związane są między innymi z uwzględnianiem różnych składowych odpowiedzialnych za konsumpcję energii elektrycznej w pompie ciepła, czy rozpatrywany jest stan ustalony czy nieustalony oraz czy pompa ciepła pracuje z nominalnym czy częściowym obciążeniem. Wyniki obliczeń porównano z wartościami współczynników, które zostały określone na drodze teoretycznej.