            <title-group>
                                    <article-title>Multicriteria diagnosis of synchronous machine using the welch method</article-title>
                                    <article-title>Multicriteria diagnosis of synchronous machine using the welch method</article-title>
                            </title-group>

                        <contrib-group>
                                                            <contrib contrib-type="author" corresp="no">
                            <name>
                                <surname>Ferreira</surname>
                                <given-names>José Gregorio</given-names>
                            </name>
                            <role>author</role>
                                                                                                                                    <xref ref-type="aff" rid="aff-1"/>
                                                                                        <xref ref-type="corresp" rid="cor-1"/>
                        </contrib>
                                            <contrib contrib-type="author" corresp="no">
                            <name>
                                <surname>Sobczyk</surname>
                                <given-names>Tadeusz J.</given-names>
                            </name>
                            <role>author</role>
                                                                                                                                    <xref ref-type="aff" rid="aff-2"/>
                                                                                        <xref ref-type="corresp" rid="cor-2"/>
                        </contrib>
                                            <contrib contrib-type="author" corresp="no">
                            <name>
                                <surname>Warzecha</surname>
                                <given-names>Adam </given-names>
                            </name>
                            <role>author</role>
                                                                                                                                    <xref ref-type="aff" rid="aff-3"/>
                                                                                        <xref ref-type="corresp" rid="cor-3"/>
                        </contrib>
                                                </contrib-group>

                                                                                        <aff id="aff-1">
                    <institution-wrap>
                        <institution>Faculty of Electrical and Computer Engineering, Cracow University of Technology</institution>
                                            </institution-wrap>
                </aff>
                                                                                            <aff id="aff-2">
                    <institution-wrap>
                        <institution>Instytut Elektromechanicznych Przemian Energii, Wydział Inżynierii Elektrycznej i Komputerowej, Politechnika Krakowska</institution>
                                            </institution-wrap>
                </aff>
                                                                                            <aff id="aff-3">
                    <institution-wrap>
                        <institution>Uniwersytet Śląski w Katowicach</institution>
                                            </institution-wrap>
                </aff>
                            
            <author-notes>
                                    <corresp id="cor-1">Correspondence to: José Gregorio Ferreira <email></email></corresp>
                                    <corresp id="cor-2">Correspondence to: Tadeusz J. Sobczyk <email></email></corresp>
                                    <corresp id="cor-3">Correspondence to: Adam  Warzecha <email></email></corresp>
                            </author-notes>

                            <pub-date date-type="pub" publication-format="electronic" iso-8601-date="2015-12-16">
                    <day>16</day>
                    <month>12</month>
                    <year>2015</year>
                </pub-date>
            
            <volume>Elektrotechnika Zeszyt 1-E (8) 2015</volume>
            <issue>2015</issue>
                        <fpage>343</fpage>
                                    <lpage>352</lpage>
            
            <permissions>
                <copyright-statement>Copyright &#x00A9; 2015</copyright-statement>
                                    <copyright-year>2015</copyright-year>
                            </permissions>

            <funding-group specific-use="Crossref">
                <funding-statement></funding-statement>
            </funding-group>
        </article-meta>
    </front>
    <body>
        &lt;p style=&quot;text-align: justify;&quot;&gt;
	This paper discusses the detection of internal faults in the stator and rotor windings of synchronous machines. Using current signature analysis, it is demonstrated how by using low cost equipment, it is possible to detect the fault by monitoring the currents. The process of detection is totally optimized, and the processing time is enough to identify the fault before the total machine damage. Using the spectrum of the healthy machine as a reference, the followed methodology allows the timely and reliable detection of faults.&lt;/p&gt;