TY - JOUR TI - Matrix FMEA analysis with cause-effect diagram for selected fluid power component AU - Fabiś-Domagała, Joanna AU - Domagała, Mariusz TI - Matrix FMEA analysis with cause-effect diagram for selected fluid power component AB - This paper presents an application of matrix FMEA analysis and cause-effect diagram for a double acting hydraulic cylinder. A decomposition of the investigated cylinder has been made and main functions and potential failures for the pair-function relation have been identified. Elements with the greatest probability of failure and cause-effect relationship have been determined. VL - 2017 IS - Volume 10 Year 2017 (114) PY - 2017 SN - 0011-4561 C1 - 2353-737X SP - 141 EP - 146 DO - 10.4467/2353737XCT.17.179.7287 UR - https://ejournals.eu/en/journal/czasopismo-techniczne/article/matrix-fmea-analysis-with-cause-effect-diagram-for-selected-fluid-power-component KW - FMEA KW - cause and effect diagram