TY - JOUR TI - The low-frequency measuring method of voltage, current, power and signal processing application for compact PLC AU - Gębarowski, Robert AU - Jaraczewski, Marcin AU - Mielnik, Anna TI - The low-frequency measuring method of voltage, current, power and signal processing application for compact PLC AB - This article presents the implementation of the low-frequency measuring method of current and voltage RMS values as well as active and reactive power of a two-terminal network, which is supplied by a sinusoidal voltage of 50 Hz. The implementation was made on a typical compact PLC-FX3G Mitsubishi Electric controller. This controller has a relatively low computing power, and when control tasks and measurements are performed simultaneously, the measurement method must be simple in order to match the limited computing power of the controller. This article describes how to implement the low-frequency measuring method onto the controller. It also presents the laboratory set for testing the controller and application. The paper also presents the results of measurements and calculations, in particular the impact of measurement time delays on errors of the RMS voltage and current values as well as active and reactive power values. VL - 2016 IS - Electronical Engineering Issue 2-M 2016 PY - 2016 SN - 0011-4561 C1 - 2353-737X SP - 121 EP - 134 DO - 10.4467/2353737XCT.16.252.6051 UR - https://ejournals.eu/en/journal/czasopismo-techniczne/article/the-low-frequency-measuring-method-of-voltage-current-power-and-signal-processing-application-for-compact-plc KW - digital measurement of voltage KW - current and power KW - PLCs KW - measuring errors