TY - JOUR TI - Influence of higher harmonics on losses in induction machines AU - Lerch, Tomasz AU - Rad, MichaƂ TI - Influence of higher harmonics on losses in induction machines AB - The paper summarizes the power loss results in induction machines supplied with distorted voltage. The voltage waveform contained the fifth and seventh harmonics components of adjustable level in the range of 0% to 30%. The influence of the harmonic content on the core and windings losses is of particular interest. The paper investigates the additive impacts of basic and additional losses resulting from distorted power supply conditions. VL - 2016 IS - Elektrotechnika Zeszyt 3-E 2016 PY - 2016 SN - 0011-4561 C1 - 2353-737X SP - 13 EP - 24 DO - 10.4467/2353737XCT.16.262.6061 UR - https://ejournals.eu/czasopismo/czasopismo-techniczne/artykul/influence-of-higher-harmonics-on-losses-in-induction-machines KW - induction machine losses KW - efficiency standards KW - power quality