%0 Journal Article %T The hygrothermal aspects of forming the internal structure of the roof slope %A Chądzyński, Andrzej %J Czasopismo Techniczne %V 2014 %R 10.4467/2353737XCT.14.197.3285 %N Architektura Zeszyt 8 A (15) 2014 %P 121-128 %K roof, layers, building physics %@ 0011-4561 %D 2014 %U https://ejournals.eu/czasopismo/czasopismo-techniczne/artykul/the-hygrothermal-aspects-of-forming-the-internal-structure-of-the-roof-slope %X The system of external, sloping construction barriers protecting the bearing structure and the building’s interior from the influence of environment’s adverse weather conditions is one of the crucial elements of interior’s thermal and acoustic protection. The steep roof effectively protects the interior against rain, snow, and wind. Proper thermal and damp-proof protection of the attic’s microclimate space enclosed by the roof plane requires the application of new materials, which permit the system to obtain technical and functional values complying with the contemporary requirements. The roof’s plane structure requires the use of multilayered construction barrier functioning as an oblique outer wall.